UPFLOW BOTTOM FILTER INSTALLATION
I332
FIGURE 4
UPFLOW SIDE FILTER LOCATION
MAINTENANCE
DISCONNECT MAIN ELECTRICAL
POWER TO THE UNIT BEFORE
ATTEMPTING ANY MAINTENANCE.
FAILURE TO DO SO CAN CAUSE
ELECTRICAL SHOCK RESULTING
IN SEVERE PERSONAL INJURY OR
DEATH.
DO NOT OPERATE YOUR SYSTEM
FOR EXTENDED PERIODS WITHOUT
FILTERS. A PORTION OF THE DUST
ENTRAINED IN THE AIR MAY
TEMPORARILY LODGE IN THE AIR
DUCT RUNS AND AT THE SUPPLY
REGISTERS. ANY RECIRCULATED
DUST PARTICLES WILL BE HEATED
AND CHARRED BY CONTACT WITH
THE FURNACE HEAT EXCHANGER.
THIS RESIDUE WILL SOIL CEILINGS,
WALLS, DRAPES, CARPETS, AND
OTHER HOUSEHOLD ARTICLES.
IT IS RECOMMENDED THAT AN
ANNUAL INSPECTION OF YOUR
FURNACE BE DONE BY A
QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.
WARNING
!
CAUTION
!
JACKET
FILTER
FILTER
ROD
FILTER
ROD
FILTER
JACKET ASSEMBLY
FILTER ROD
SUPPORT
ANGLE
FILTER
SUPPORT
ANGLE
UPFLOW FILTER SIZES
FURNACE INPUT BOTTOM SIDE
WIDTH MBTUH SIZE SIZE
QUANTITY
17
1
2 45, 60 15
3
4 X 25 15
3
4 X 25 1
21 90 19
1
4 X 25 15
3
4 X 25 1