Rheem 2-stage Manuel d'utilisation et d'entretien Page 4

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 3
4
FOR YOUR SAFETY READ BEFORE OPERATING
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
NOTE: Read and follow the Safety Information, Operating Instructions and
Instructions To Turn Off Gas To Appliance located on the furnace. This label
will have specific information regarding the furnace and its gas controls.
WARNING
!
FIGURE 3
TYPICAL GAS VALVE
LIGHTING INSTRUCTIONS
DIRECT SPARK IGNITION
This appliance is equipped with a direct
spark ignition device. This device lights
the main burners each time the room
thermostat (closes) calls for heat. See
lighting instructions on the furnace.
TO START FURNACE
1. BE SURE THAT THE MANUAL
GAS
CONTROL HAS BEEN IN THE
“OFF” POSITION FOR AT LEAST
FIVE MINUTES. DO NOT ATTEMPT
TO MANUALLY LIGHT THE MAIN
BURNERS. FAILURE TO FOLLOW
THIS WARNING CAN CAUSE A
FIRE OR AN EXPLOSION
RESULTING IN PROPERTY
DAMAGE, PERSONAL INJURY OR
DEATH.
2. Set the room thermostat to the lowest
setting.
3. Turn the gas control knob to the “On”
position, or set the gas control switch
to the “On” position.
4. Replace the control access door.
5. Turn on the electrical power.
6. Set the room thermostat to “Heat”
one point above room temperature to
light the main burners. After the
burners are lit, set room thermostat to
a desired temperature.
TO SHUT DOWN FURNACE
1. Set the room thermostat to its lowest
setting. Turn the thermostat to “Off.”
2. Shut off the gas to main burners by
turning the gas control switch to the
“Off” position, or by setting the gas
control switch to the “Off” position.
SHOULD OVERHEATING OCCUR OR
THE GAS SUPPLY FAIL TO SHUT
OFF, SHUT OFF THE MANUAL GAS
VALVE TO THE APPLIANCE BEFORE
SHUTTING OFF THE ELECTRICAL
SUPPLY. FAILURE TO DO SO CAN
CAUSE AN EXPLOSION OR FIRE
RESULTING IN PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.
!
WARNING
!
WARNING
Manual
gas control
switch shown
in “ON”
position.
Vue de la page 3
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire