Stellar Service Instructions REV: D
Date of Issue: 14/09/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”.
11
HIGH EFFICIENCY WATER HEATERS
When the water heater is first lit, or after a large usage of
hot water, condensation may form on the burner and flue
terminal.
This is quite normal, especially in winter months, and will
dry off as the water is heated.
NOTE: During heating cycles it is not unusual to see
water vapour clouds streaming from the flue terminal.
This is normal operation of the water heater.
The plastic drain near the bottom left-hand side of the
water heater will drip water during the heating cycle. It is
possible for SEVERAL LITRES a day of condensation to
discharge from the drain especially in cool conditions.
This water is not from the mains supply but is
condensation caused by the efficient operation of the
water heater.
FAULT FINDING CHARTS
Fault Chart number Page
No hot water Pilot fault 1, 1.1, 1.2 13, 14, 15
Main burner fault 2 16
Leaking water heater 3 19
Insufficient hot water 4 20
Water too hot 5 21
Stacking 5.1, 5.2 22
Noisy water heater 6 23
Intermittent operation 7 24