TM011 H.S.I Heavy Duty Gas Service Instructions
D.O.I: 03/06
This document is stored and maintained electronically by
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
19
Fault Finding - Chart 1
Is the
thermostat display
blank?
Power Supply
Is
there power
at the terminal
block?
YES
1
YES
Is
there power
at the
GPO?
NO
Test 1
Replace cord
Test 2
Yes
Refer to electricianNO
Are the
thermostat contacts
closed?
NO
Is the water
temperature at or
above the thermostat
setting?
NO
Test 3
Increase the set point above
the current water temperature
by at least 5 degrees
YES
2
NO
Test 4
Is
there power
at the ignition
module?
YES
Test 5
Does
the burner
light?
YES
Refer to ignition
module section
NO
Is the
complaint for
intermittent
operation?
YES
3
YES
4
Insufficient hot water
5
Water too hot
6
Leaking
Is
a power flue or
mechanical venting
system installed?
NO
Is
the sail or
pressure switch
closed?
YES Refer to installerNO
Refer to flue damper
section
Refer to fan module
section
Wiring loom open
circuit. Check for
breaks or damaged
wiring
Test 6
Select model
YES
NO
621275
631275
621265
631265
1.1
1.2