Rheem Air Handlers
FORM NO. H11-549
RHLP- Standard Efficiency
X-13 (ECM) Motor
RHLP features an X-13 (ECM) motor which provides enhanced
SEER performance with most Rheem outdoor units.
•1
1
/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between
42
1
/2 to 55
1
/2 inches [1080 to 1410 mm] tall and 22 inches
[559 mm] deep.
Versatile 4-way convertible design for upflow, downflow, hori-
zontal left and horizontal right applications.
Factory-installed high efficiency indoor coil.
All models meet or exceed 330 to 400 CFM [156 to 189 L/s]
per ton at .3 inches [.7 kPa] of external static pressure.
Enhanced airflow up to .7" external static pressure.
Sturdy construction with 1.0 inch [.24 kPa] of reinforced foil
faced jacket insulation for excellent thermal and sound
insulation.
Field-installed auxiliary electric heater kits provide exact heat
for indoor comfort. Kits include circuit breakers which meet UL
and cUL requirements for service disconnect.
Suitable for R-410A or R-22 Refrigerants with piston change.
Air
Air Handlers
RHLP Series
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Rheem Air Handlers

Rheem Air HandlersFORM NO. H11-549RHLP- Standard EfficiencyX-13 (ECM) Motor• RHLP features an X-13 (ECM) motor which provides enhancedSEER performance

Page 2 - TABLE OF CONTENTS

AirElectrical DataRHLP Series10Electrical Data – Blower Motor Only – No Electric HeatModelRHLPVoltageApplicationPhase*Hertz HP [W] RPM SpeedsCircuitAm

Page 3 - Engineering Features

AirElectrical DataRHLP Series11Electrical Data – With Electric HeatInstallation of the U.L. Listed original equipment manufacturer provided heater kit

Page 4 - Model Number Identification

AirElectrical DataRHLP Series12Electrical Data – With Electric Heat (con’t.)Installation of the U.L. Listed original equipment manufacturer provided h

Page 5 - Unit Dimensions

AirElectrical WiringRHLP Series13Electrical WiringPower Wiring• Field wiring must comply with the National Electrical Code(C.E.C. in Canada) and any a

Page 6 - Airflow Directional Data

AirLimited WarrantyRHLP Series14GENERAL TERMS OF LIMITED WARRANTY*Rheem will furnish a replacement for any part of this productwhich fails in normal u

Page 8 - Airflow Performance Data

The new degree of comfort.™Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com In keeping with

Page 9

AirTable of ContentsRHLP Series2TABLE OF CONTENTSEngineering Features ...

Page 10

AirEngineering FeaturesRHLP Series3Engineering FeaturesRHLP- Series The most compact unit design available, all standard heat airhandler models only

Page 11 - RHLP Series

Air4Model Number IdentificationRHLP SeriesModel Number IdentificationRHLP—HM2417JADesign VariationA = 1st DesignVoltageA = 115/1/60J = 208/240/1/60Cab

Page 12

5ELECTRICAL CONNECTIONSMAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7/8 [22.2 mm],13/32 [27.8 mm], 131/32 [50 mm] DIA. KNOCKOUTS. LOW VOLTAG

Page 13 - Accessories-Kits—Parts

AirAirflow Directional DataRHLP Series6Airflow Directional DataUPFLOW DOWNFLOWHORIZONTAL RIGHTHAND AIRFLOWHORIZONTAL LEFTHAND AIRFLOW

Page 14

AirAirflow Performance DataRHLP Series7Airflow PerformanceAirflow performance data is based on cooling performancewith a coil and no filter in place.

Page 15

AirAirflow Performance DataRHLP Series8External Static Pressure—Inches W.C. [kPa]X-13 CFM [L/s] Air Delivery/RPM/Watts—115/208/240 VoltsRPM 608Blower

Page 16 - The new degree of comfort

AirAirflow Performance DataRHLP Series9External Static Pressure—Inches W.C. [kPa]PSC CFM [L/s] Air Delivery/RPM/Watts—115/208/240 VoltsRPM 660Blower S