FORM NO. P11-769 REV. 5Supersedes Form No. P11-769 Rev. 4Featuring Industry Standard R-410A RefrigerantRQNM- 13-SEER SERIESNOMINAL SIZES 2-5 TONS [7-1
10GENERAL DATA—RQNM- SERIESModel RQNM- Series A060CK A060JKCooling Performance1Gross Cooling Capacity Btu [kW] 62,000 [18.17] 62,000 [18.17]EER/SEER2
Model RQPM- Series A024JK A030JK A036CK A036JKCooling Performance1Gross Cooling Capacity Btu [kW] 24,000 [7.03] 29,400 [8.61] 36,000 [10.55] 36,000 [
Model RQPM- Series A037CK A037JK A042CK A042JKCooling Performance1Gross Cooling Capacity Btu [kW] 36,000 [10.55] 36,000 [10.55] 44,000 [12.89] 44,000
13GENERAL DATA—RQPM- SERIESModel RQPM- Series A043CK A043JK A048CK A048JKCooling Performance1Gross Cooling Capacity Btu [kW] 43,500 [12.75] 43,500 [1
Model RQPM- Series A049CK A049JK A060CK A060JKCooling Performance1Gross Cooling Capacity Btu [kW] 49,000 [14.36] 49,000 [14.36] 61,000 [17.87] 61,000
15GENERAL DATA—RQRM- SERIESModel RQRM- Series A030JK A036JK A048JKCooling Performance1Gross Cooling Capacity Btu [kW] 29,600 [8.67] 35,000 [10.25] 46
NOTES:1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does notinclude the effect of
GROSS SYSTEMS PERFORMANCE DATA—RQNM-A030ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1200 [566] 100
GROSS SYSTEMS PERFORMANCE DATA—RQNM-A042ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1740 [821] 145
GROSS SYSTEMS PERFORMANCE DATA—RQNM-A060ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 2280 [1076] 19
2TABLE OF CONTENTSUnit Features & Benefits ...3-6Model Identification O
GROSS SYSTEMS PERFORMANCE DATA—RQPM-A030ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1200 [566] 100
GROSS SYSTEMS PERFORMANCE DATA—RQPM-A037ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1440 [680] 120
GROSS SYSTEMS PERFORMANCE DATA—RQPM-A043ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1740 [821] 142
GROSS SYSTEMS PERFORMANCE DATA—RQPM-A049CKENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1860 [878] 1
GROSS SYSTEMS PERFORMANCE DATA—RQPM-A060ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 2280 [1076] 19
GROSS SYSTEMS PERFORMANCE DATA—RQRM-A036ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1440 [680] 120
GROSS SYSTEMS PERFORMANCE DATA—RQRM-A048ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]CFM [L/s] 1860 [878] 152
HEATING PERFORMANCE DATA—RQNM-A024IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 960 [453] 800 [378] 640 [302] 960 [45
HEATING PERFORMANCE DATA—RQNM-A036IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 1440 [680] 1200 [566] 960 [453] 1440
HEATING PERFORMANCE DATA—RQNM-A048IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 1860 [878] 1500 [732] 1240 [585] 1860
UNIT FEATURES & BENEFITS—RQNM/RQPM/RQRM- SERIES3The RQNM, RQPM & RQRM series of Package Heat Pumps aredesigned to be the most efficient, quick
HEATING PERFORMANCE DATA—RQPM-A024IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 960 [453] 800 [378] 640 [302] 960 [45
HEATING PERFORMANCE DATA—RQPM-A036IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 1440 [680] 1200 [566] 960 [453] 1440
HEATING PERFORMANCE DATA—RQPM-A042IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 1740 [821] 1450 [684] 1160 [547] 1740
HEATING PERFORMANCE DATA—RQPM-A048IDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 1860 [878] 1550 [732] 1240 [585] 1860
HEATING PERFORMANCE DATA—RQPM-A049JKIDB —Indoor air dry bulb5[-15]Total BTUH [kW]Power27.7 [8.12]2.327.3 [8.00]2.426.9 [7.88]2.426.3 [7.71]2.726.0 [7.
35SYSTEMS PERFORMANCE—RQRM- SERIESHEATING PERFORMANCE DATA—RQRM-A030JKIDB —Indoor air dry bulbIDB 60°F [15.5°C] 70°F [21.1°C] 80°F [26.7°C]CFM [L/s] 1
36SYSTEMS PERFORMANCE—RQRM- SERIESHEATING PERFORMANCE DATA—RQRM-A048JKIDB —Indoor air dry bulb[ ] Designates Metric ConversionsIDB 60°F [15.5°C] 70°F
External Static Pressure—Inches W.C. [kPa]CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet CoilRPM 533Blower Size/MotorHP [W] &# of S
External Static Pressure—Inches W.C. [kPa]CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet CoilRPM 498NominalCoolingCapacityTons [kW]Moto
External Static Pressure—Inches W.C. [kPa]CFM [L/s] Air Delivery/RPM/Watts—230 Volts Side Discharge—Wet CoilRPM 603Blower Size/MotorHP [W] &# of S
4UNIT FEATURES & BENEFITS—RQNM/RQPM/RQRM- SERIESWhile other manufacturers have chosen to use pre-painted steelin their equipment, which exposes ra
External Static Pressure—Inches W.C. [kPa]CFM [L/s] Air Delivery/RPM/Watts—208 Volts Side Discharge—Wet CoilRPM 603Blower Size/MotorHP [W] &# of S
External Static Pressure—Inches W.C. [kPa]InchesWCRecommendedAirflow RangeMotorSpeed/TapSetting0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [
ELECTRICAL DATA – RQNM SERIESMinimum Circuit Ampacity 20/20Unit InformationUnit OperatingVoltage Range187-253Minimum OvercurrentProtection Device Size
ELECTRICAL DATA – RQPM SERIESMinimum Circuit AmpacityMinimum OvercurrentProtection Device Size23/2330/30Maximum OvercurrentProtection Device Size35/35
ELECTRICAL DATA – RQPM SERIESMinimum Circuit AmpacityMinimum OvercurrentProtection Device Size25/2525/25Maximum OvercurrentProtection Device Size35/35
ELECTRICAL DATA – RQRM SERIESVolts 208/230Unit InformationUnit OperatingVoltage Range187-253Minimum OvercurrentProtection Device Size25/25Maximum Over
5.4/7.2C07J 1 18.42/24.56 26/30 53/58 60/60208-240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION—3.6/4.860
A036CNo Heat — — — 17/17 20/25 20/25C15C 3 36.85/49.13 30.1/34.7 55/61 60/60 70/70C10C 2 24.57/32.76 20/23.1 42/46 45/45 50/5038/44 40/45 — — —— — 17/
5.4/7.2C07J 1 18.42/24.56 26/30 55/60 60/60208-240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION—3.6/4.860
A036CA037CNo Heat — — — 19/19 25/25 25/25C15C 3 36.85/49.13 30.1/34.7 57/61 60/60 70/70C10C 2 24.57/32.76 20/23.1 44/48 45/45 50/5038/44 40/45 — — ——
5UNIT FEATURES & BENEFITS—RQNM/RQPM/RQRM- SERIESThe indoor-section top cover also easily opens to access theremovable blower housing and motor ().
208/240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATIONRatedHeater kW@ 208/240 VHeater Kit Heat PumpUnitMode
51UNIT DIMENSIONS—RQNM/RQPM/RQRM- SERIES[ ] Designates Metric Conversions[ ] Designates Metric ConversionsModelRQNM, RQPM: 024, 030, 036RQRM: 024RQNM,
52TYPICAL INSTALLATIONS[ ] Designates Metric Conversions[ ] Designates Metric Conversions
ACCESSORY EQUIPMENTAccessoryDescriptionModelApplicationAccessoryModel No.Outdoor Thermostat RQNM/RQPM/RQRM RXPT-A01Thermostats RQNM/RQPM/RQRM See Ther
54WIRING SCHEMATICS—RQNM- SERIES
55WIRING SCHEMATICS—RQNM- SERIES
56WIRING SCHEMATICS—RQPM- SERIES
57WIRING SCHEMATICS—RQPM- SERIES
58WIRING SCHEMATICS—RQPM- SERIES
59WIRING SCHEMATICS—RQPM- SERIES
Low pressure control standard on all models ().High pressure control standard on -060 model. 206UNIT FEATURES & BENEFITS—RQNM/RQPM/RQRM- SERIESHig
BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROMYOUR RETAILER.Rheem will furnish a replacement f
7MODEL IDENTIFICATION—RQNM/RQPM/RQRM- SERIESR Q N M — A 036 J K 010Heating Capacity (Factory Installed)000 = No Resistance Heat005 = 05 KW Resistance
8GENERAL DATA—RQNM- SERIESModel RQNM- Series A024JK A030JK A036CK A036JKCooling Performance1Gross Cooling Capacity Btu [kW] 24,600 [7.21] 29,800 [8.7
9GENERAL DATA—RQNM- SERIESModel RQNM- Series A042CK A042JK A048CK A048JKCooling Performance1Gross Cooling Capacity Btu [kW] 43,500 [12.75] 43,500 [12
Commentaires sur ces manuels